Three (3) individual penetrator assemblies are inserted through pre-drilled holes in the tubing hanger.
All metal to metal seals provide dual barrier sealing in each penetrator and secure them to the tubing hanger.
No cable splice is made. To complete the connection, simply attach three male connector ends to the pump cable and plug all three male and female connections together.
Simple surface installation.
Three flexible fittings with Swagelok end connections seal off in the penetrator above the tubing head adaptor.
An articulating bracket fixes the surface hardware firmly to the wellhead.
Reusable explosion proof and safe surface conduit system (LBDN) and breather is provided at the wellhead to allow for simple surface connection.
U.L. listed surface cable (CLX) is terminated and sealed in the conduit system for required length to reach the motor control panel.
Specifications
Voltage: 5000 VAC, 3 Phase
Amperage: 150 Amps Continuous 190 Amps Max
Pressure: 5,000 p.s.i. API W.P. (10,000 p.s.i. Proof Test)